10kv class three-phase oil-immersed distribution transformer

Primary Voltage Rating:6kV,6.3kV,10kV,10.5kV,11kV
Secondary Voltage:0.4kv or others
Rated power:30kva-3150kva
H.V. TAP RANGE: ±2×2.5%
Winding connection: Dyn11/ Yyn0
Winding material: Copper/Aluminum
Cooling Method: ONAN / ONAF
Tapping Method: OLTC/OCTC All available
Standard:IEC60076,ISO9001,GB,ANSI,CSA

Min. order quantity: ≧ 1 set
Packaging Details: International wooden cases or according to the actual transport needs
delivery time: Generally it is 20 days if the goods are in stock, or 30 days if the goods are not. It is according to the quantity.
Payment Method: TT, Western Union, L/C

GE Transformer develops and produces S11-M series fully sealed oil-immersed power transformers with the advantages of low loss, low noise, and high efficiency, which can achieve good energy-saving effects and reduce pollution. Compared with ordinary oil-immersed transformers, the fully sealed transformer cancels the oil storage cabinet, the change of oil volume is compensated by the elasticity of the corrugated oil tank’s corrugated sheet to adjust automatically, the transformer is isolated from air, preventing and slowing down the deterioration of oil and insulation aging, enhance the operation reliability, normal operation maintenance-free

Three phase oil immersed transformer features

1. The transformer core adopts imported cold-rolled silicon steel sheet stacked, which greatly reduces no-load loss and no-load current, and ties the core to ensure the tightness of the core and reduce noise.
2, high and low voltage winding with oxygen-free copper winding, low voltage winding 500kVA and below using double cylinder structure. 630kVA and above using double spiral or four spiral structure, high voltage winding using multi-layer cylinder structure.
3 The transformer connection group adopts Dyn11, reduces the impact of harmonics on the grid, and changes the quality of the power supply.
4、Transformer is a fully sealed structure, prolonging the service life, free of lifting core, and free of maintenance.
5、The actual measured noise value is lower than the standard.
This series of transformers by regular transport, no need to lift the core check, can install the relevant parts, acceptance project test, after passing can be put into operation

Using Environment

Ambient temperature:-20°C to +40°C
Altitude: Conventional is used below 2000 meters, more than 2000 meters need to be customized

TypeRated power
(kVA)
Winding connectionVoltage combination(kV)No-load loss
(W)
Dy On-load loss
(W)
Yy On-load loss
(W)
No-load current
(%)
Short Circuit Impedance
(%)
High voltageVoltage regulation rangeLow voltage
S13-M-3030Yyn0
or
Dyn11
10
6.3
6
士5%

土2×2.5%
0.4806306001.54
S13-M-50501009108701.3
S13-M-6363110109010401.2
S13-M-8080130131012501.2
S13-M-100100150158015001.1
S13-M-125125170189018001.1
S13-M-160160200231022001
S13-M-200200240273026001
S13-M-250250290320030500.9
S13-M-315315340383036500.9
S13-M-400400410452043000.8
S13-M-500500480541051500.8
S13-M-63063057062000.64.5
S13-M-80080070075000.6
S13-M-10001000830103000.6
S13-M-12501250970120000.5
S13-M-160016001170145000.5
S13-M-200020001550183000.45
S13-M-250025001830212000.4
TypeRated power
(kVA)
Winding connectionVoltage combinationNo-load loss
(W)
On-load loss(W)No-load current
(%)
Short Circuit Impedance
(%)
High voltageVoltage regulation rangeLow voltage
S11-M-30 30  Yyn0

  or
Dyn11
6
6.3
10
10.5
11
±5%
or
±2×2.5%
0.4100630/6002.34.0
S11-M-50 50130910/8702.04.0
S11-M-63 63150   1090/10401.94.0
S11-M-80 80180   1310/12501.94.0
S11-M-100 100200   1580/15001.84.0
S11-M-125 125240   1890/18001.74.0
S11-M-160 160280   2310/22001.64.0
S11-M-200 200340   2730/26001.54.0
S11-M-250 250400   3200/30501.44.0
S11-M-315 315480   3830/36501.44.0
S11-M-400 400570   4520/43001.34.0
S11-M-500 500680   5410/51001.24.0
S11-M-630 630810 62001.14.5
S11-M-800 800980 75001.04.5
S11-M-100010001150 103001.04.5
S11-M-125012501360 128000.94.5
S11-M-160016001640 145000.84.5
S11-M-200020002280 178200.65.0
S11-M-250025002700 207000.65.0