11kv class cast resin dry type distribution transformer

Primary Voltage Rating:6kV,6.3kV,10kV,10.5kV,11kV,13.2KV
Secondary Voltage:0.4kv or others
Rated power:30kva-3150kva
H.V. TAP RANGE: ±2×2.5%
Winding connection: Dyn11/ Yyn0
Winding material: Copper/Aluminum
Cooling Method: AN / AF
Tapping Method: OLTC/OCTC
Standard:IEC60076,GB20052-2020,ISO9001,ANSI,CSA

Min. order quantity: ≧ 1 set
Packaging Details: International wooden cases or according to the actual transport needs
delivery time: Generally it is 20 days if the goods are in stock, or 30 days if the goods are not. It is according to the quantity.
Payment Method: TT, Western Union, L/C

GE Transformer produces dry-type transformers whose performance indexes conform to IEC60076, GB20052-2020, ISO9001, ANSI, CSA, and other international standards, which are proven by users to be reliable in operation and reach international advanced level. The series products adopt the world’s advanced manufacturing technology, the design drawings and technical documents are complete, correct, and clear, the production equipment is advanced, the manufacturing process is stable, the measurement means are complete, and we can complete the design and production within 2-3weeks, providing strong support and solid guarantee for customers.

Advantages of dry-type transformers:

  1. Because of the advantages of strong short-circuit resistance, low maintenance workload, high operational efficiency, small size, and low noise, dry-type transformers are often used in places with high performance requirements such as fire prevention and explosion protection. They are safe, fireproof, non-polluting, and can be used directly for high-load power consumption;
    High mechanical strength, high short-circuit resistance, small partial discharge, good thermal stability, high reliability, and long service life due to the adoption of advanced technology in China.
  2. Low loss, low noise, obvious energy-saving effect, and maintenance-free.
  3. Good heat dissipation performance, strong overload capability, and short-time over-capacity operation under forced cooling;
  4. It has a certain moisture-proof performance and can be operated under the harsh environment of high humidity.
  5. The dry-type transformer can be equipped with a complete temperature detection and protection system. An intelligent signal temperature control system is used to automatically detect and display the operating temperature of each of the three phase windings and to automatically start and stop the shutdown unit, with alarm and trip settings.
  6. Small size, lightweight, low space requirement, and low installation cost.

Using Environment

Altitude: Conventional is used below 2000 meters, more than 2000 meters need to be customized
Ambient temperature:
Highest air temperature +45ºC
Minimum outdoor air temperature -15ºC
Scope of application:
10kv dry type transformer can be used for power distribution in heavy load centers represented by commercial areas, factories, hospitals, airports, tunnels, chemical factories, shipyards, etc.

TypeRated power
(kVA)
Winding connectionVoltage combination(kV)No-load loss
(W)
On-load loss(W)No-load current
(%)
Short Circuit Impedance
(%)
High voltageVoltage regulation rangeLow voltage
SC12-3030Yyn0或
Dyn11
10
6.3
6
±5%
±2×2.5%

+ ×2.5%
0.415071024
SC12-505021510002
SC12-808029513801.5
SC12-10010032015701.5
SC12-12512537518501.3
SC(B)12-16016043021301.3
SC(B)12-20020049525301.1
SC(B)12-25025057527601.1
SC(B)12-31531570534701
SC(B)12-40040078539901
SC(B)12-50050093048801
SC(B)12-630630107058800.85
SC(B)12-630630104059600.856
SC(B)12-800800121069600.85
SC(B)12-10001000141081300.85
SC(B)12-12501250167096900.85
SC(B)12-160016001960117000.85
SC(B)12-200020002440144000.7
SC(B)12-250025002880171000.7
TypeRated power
(kVA)
Winding connectionVoltage combination(kV)No-load loss
(W)
On-load loss(W)No-load current
(%)
Short Circuit Impedance
(%)
High voltageVoltage regulation rangeLow voltage
SC13-30   30Yyn0或
Dyn11
10
6.3
6
±5%
±2×2.5%

+ ×2.59%
0.4135   64024
5C13-50   50195   9002
5C13-80   80265   12401.5
SC13-100   100290   14101.5
SC13-125   125340   16601.3
SC(B)13-160   160385   19101.3
SC(B)13-200   200445   22701.1
SC(B)13-250   250515   24801.1
SC(B)13-315   315635   31201
SC(B)13-400   400705   35901
SC(B)13-500   500835   43901
SC(B)13-630   630965   52900.85
SC(B)13-630   630935   53600.856
SC(B)13-800   8001090   62600.85
SC(B)13-1000   10001270   73100.85
SC(B)13-1250   12501500   87200.85
SC(B)13-1600   16001760   105000.85
SC(B)13-2000   20002190   130000.7
SC(B)13-2500   25002590   154000.7