10kv class three-phase oil-immersed distribution transformer

10kv class three-phase oil-immersed distribution transformer

Primary Voltage Rating:6kV,6.3kV,10kV,10.5kV,11kV
Secondary Voltage:0.4kv or others
Rated power:30kva-3150kva
H.V. TAP RANGE: ±2×2.5%
Winding connection: Dyn11/ Yyn0
Winding material: Copper/Aluminum
Cooling Method: ONAN / ONAF
Tapping Method: OLTC/OCTC All available
Standard:IEC60076,ISO9001,GB,ANSI,CSA

Min. order quantity: ≧ 1 set
Packaging Details: International wooden cases or according to the actual transport needs
delivery time: Generally it is 20 days if the goods are in stock, or 30 days if the goods are not. It is according to the quantity.
Payment Method: TT, Western Union, L/C

Get a quote

Description

GE Transformer develops and produces S11-M series fully sealed oil-immersed power transformers with the advantages of low loss, low noise, and high efficiency, which can achieve good energy-saving effects and reduce pollution. Compared with ordinary oil-immersed transformers, the fully sealed transformer cancels the oil storage cabinet, the change of oil volume is compensated by the elasticity of the corrugated oil tank’s corrugated sheet to adjust automatically, the transformer is isolated from air, preventing and slowing down the deterioration of oil and insulation aging, enhance the operation reliability, normal operation maintenance-free

Three phase oil immersed transformer features

1. The transformer core adopts imported cold-rolled silicon steel sheet stacked, which greatly reduces no-load loss and no-load current, and ties the core to ensure the tightness of the core and reduce noise.
2, high and low voltage winding with oxygen-free copper winding, low voltage winding 500kVA and below using double cylinder structure. 630kVA and above using double spiral or four spiral structure, high voltage winding using multi-layer cylinder structure.
3 The transformer connection group adopts Dyn11, reduces the impact of harmonics on the grid, and changes the quality of the power supply.
4、Transformer is a fully sealed structure, prolonging the service life, free of lifting core, and free of maintenance.
5、The actual measured noise value is lower than the standard.
This series of transformers by regular transport, no need to lift the core check, can install the relevant parts, acceptance project test, after passing can be put into operation

Using Environment

Ambient temperature:-20°C to +40°C
Altitude: Conventional is used below 2000 meters, more than 2000 meters need to be customized

 
Type Rated power
(kVA)
Winding connection Voltage combination No-load loss
(W)
On-load loss(W) No-load current
(%)
Short Circuit Impedance
(%)
High voltage Voltage regulation range Low voltage
S11-M-30  30   Yyn0

  or
Dyn11

6
6.3
10
10.5
11
±5%
or
±2×2.5%
0.4 100 630/600 2.3 4.0
S11-M-50  50 130 910/870 2.0 4.0
S11-M-63  63 150    1090/1040 1.9 4.0
S11-M-80  80 180    1310/1250 1.9 4.0
S11-M-100  100 200    1580/1500 1.8 4.0
S11-M-125  125 240    1890/1800 1.7 4.0
S11-M-160  160 280    2310/2200 1.6 4.0
S11-M-200  200 340    2730/2600 1.5 4.0
S11-M-250  250 400    3200/3050 1.4 4.0
S11-M-315  315 480    3830/3650 1.4 4.0
S11-M-400  400 570    4520/4300 1.3 4.0
S11-M-500  500 680    5410/5100 1.2 4.0
S11-M-630  630 810  6200 1.1 4.5
S11-M-800  800 980  7500 1.0 4.5
S11-M-1000 1000 1150  10300 1.0 4.5
S11-M-1250 1250 1360  12800 0.9 4.5
S11-M-1600 1600 1640  14500 0.8 4.5
S11-M-2000 2000 2280  17820 0.6 5.0
S11-M-2500 2500 2700  20700 0.6 5.0

GE Transformer