Isolation Transformer manufacturer
GE Transformer is dedicated to the design and manufacture of industrial isolation transformers, providing solutions for low-voltage distribution systems that demonstrate exceptional performance in terms of safety, functionality, and long-term reliability. Our transformers are widely utilized in Battery Energy Storage Systems (BESS), data centers, commercial and industrial facilities, the renewable energy sector, and electric vehicle charging infrastructure, delivering efficient voltage conversion and electrical isolation while significantly enhancing power quality.
Each transformer features precision-wound copper or aluminum conductors, premium silicon steel laminations, and robust insulation systems, ensuring low losses, excellent voltage regulation, and quiet operation. GE Transformer products meet or exceed ISO, IEC, CE, and other standards, delivering efficient, enduring solutions for modern power systems.
Product series include:
Dry type isolation transformer— provide electrical isolation and voltage conversion for safe, reliable power distribution.
Drive isolation transformer—Protect variable frequency drives (VFDs) and connected equipment from transient and harmonic disturbances.
Dry type Auto transformer—Deliver compact, efficient voltage conversion where isolation is not required.
K-rated Transformer—Manage harmonic currents from nonlinear loads, minimizing overheating and maintaining system efficiency.
Harmonic Mitigating Transformer—Eliminate harmonic distortion and improve power quality through advanced winding configurations and phase-shifting designs.
Encapsulated Transformer—Featuring epoxy-encapsulated windings for effective protection against dust, moisture, and corrosive contaminants.
Industrial Isolation Transformer
Industrial Isolation Transformer Parameters
| Capacity | Single Phase: 3 to 500kVA Three Phase: 5 to 3000kVA |
| Primary Voltage | 800v 690v660v600v480v440v415v380 240v or others |
| Secondary Voltage | 800v660v600v480v440v415v380v240v120v110v or others |
| Winding Material | Copper or aluminum |
| Frequency | 60Hz (50/60Hz Optional) |
| Connection Type | Dyn11/Yyn0 or others |
| Temperature Rise | ≤115° Other temperature rise options are customizable |
| Insulation | Class F or Class H |
| Cooling Method | ANAN, The number of fans can be customized |
| Efficiency (%) | ≥98% |
| Noise level (dB) | ≤45db |
| Voltage drop | <3% |
| Enclosure Type | Protection rating up to IP65; colors and materials are customizable |
| Optional Accessories | Circuit breaker, AC contactor, Thermostat, Output leakage protection, Fuse, Inverter or others |
| Warranty | 12 Months |
| Certifications | ISO, CE, UL and other certificates |
| Minimum Order Quantity | ≥1 set |
| Packaging Details | International standard wooden crate or as per actual shipping requirements |
| Delivery Time | Generally 5-10 days, depending on order quantity |
One-stop customized solutions
GE Transformer provides flexible customization to match your exact project requirements, including:
Input Voltage: e.g., 380V / 400V / 415V / 480V or fully customized
Output Voltage: tailored to your equipment specifications
Capacity: Single Phase: 3 to 500 kVA, Three Phase: 5 to 1500 kVA
Frequency: 50Hz / 60Hz
Winding material options: copper or aluminum
Connection Type: Delta (Δ) / Wye (Y) or other configurations
Insulation Class: Class B / F / H options
Cooling Method: natural air cooling (AN) or forced air cooling (AF)
Temperature Rise: configurable based on operating conditions
Enclosure: The color and material are customizable, available in options such as 304 or 316L stainless steel
Protection Rating: IP20 / IP23 / IP44 / IP54 or higher
Tap Changer: optional taps for voltage adjustment
Mounting Options: floor-standing or customized installation design
Optional Features & Accessories:
Wheels for easy movement and flexible installation
Built-in circuit breaker for enhanced protection
AC contactor for controlled switching
Temperature controller for real-time thermal monitoring
Output leakage protection device for added safety
Fuse protection for overload and short-circuit conditions
Surge protection device (SPD) for transient voltage suppression
K-Factor design for handling harmonic-rich loads
Electrostatic shielding for superior noise and interference reduction

Why Choose GE Transformer
Quality Control: Quality is a core value of GE Transformer. We conduct Factory Acceptance Testing (FAT), type testing, and third-party inspections to ensure superior quality. We strictly adhere to the ISO 9001 quality management system, committed to providing our customers with the highest quality products.
Professional Team: Our team comprises highly skilled professionals dedicated to responding quickly to customer needs. All GE Transformer team members receive systematic training and continuously improve their capabilities through rigorous quality standards and practices. Our commitment to customer service, product innovation, engineering excellence, and social and environmental responsibility makes us a trusted partner in the global power industry.
Certifications
- ISO9001:2015
- CE Certifications:
- UL Certifications:
- CSA Certification:
- CNAS Certification:

Competitive Market Pricing:Leveraging years of industry experience, GE Transformer integrates high-quality resources across R&D, production, procurement, transportation, and service, achieving effective cost control.
Fast Delivery: Strong production capacity, multiple freight partners, and a professional pre-sales and after-sales team, adhering to the “customer first” philosophy, provide customers with fast delivery and usage services.
FAQ
1. How to Calculate Required Transformer Capacity
Formula: kVA = Load Power (kW) ÷ Power Factor (typically 0.8)
Example: 50kW equipment → 50 ÷ 0.8 = 62.5kVA (select 63kVA model)
2. Why is electrical isolation important?
Electrical isolation prevents a direct electrical path between source and load circuits, protecting personnel and equipment from electrical shock and transient disturbances. It minimizes the effects of ground loops, harmonics, and high-frequency noise that can interfere with sensitive equipment. In automation and control systems, isolation enhances signal integrity and system reliability. Rex Power Magnetics designs its transformers with high dielectric insulation and low interwinding capacitance to maximize electrical separation while maintaining energy efficiency and quiet performance.
3. Are custom dry type industrial isolation transformers available?
Yes. GE Transformer offers fully customized general purpose isolation transformers tailored to customer requirements. Options include non-standard voltage ratios, kVA ratings, special impedance levels, and custom enclosures. Our engineering team can design transformers with enhanced shielding, harmonic mitigation, or specific thermal performance targets. Each custom-built unit is produced and tested to the same rigorous standards, ensuring full compliance with applicable codes and reliable integration into specialized systems.
4. What is your minimum order quantity (MOQ)?
We support flexible MOQs. For most export orders, MOQ starts from 1 unit, especially for project-based procurement.
5. What is the typical delivery time?
Standard models typically require 15-20 days, depending on capacity, quantity, and customization requirements.
6. What maintenance is recommended for dry type industrial isolation transformers?
These transformers are low-maintenance devices. Periodic inspections should include verifying terminal tightness, ensuring unobstructed ventilation, and checking for dirt, corrosion, or insulation discoloration. The polyester resin coating minimizes moisture absorption and mechanical movement, reducing long-term maintenance needs. In dusty or high-humidity environments, more frequent cleaning and visual checks are advisable. With routine inspections and proper loading, GE Transformer isolation transformers provide decades of dependable service.
7. Do you offer customization and OEM services?
Yes, we provide full customization and OEM/ODM services based on your project requirements.
8. What information is required for a quotation?
Please provide rated power, input/output voltage, frequency, application, and any special requirements such as enclosure type or optional features.